Brooks 5850e pdf




















These products have a wide flow measurement range and are suitable for a broad range of temperature and pressure conditions making them well suited for applications in chemical and petrochemical research, laboratory, analytical, fuel cell and life science among others. The Series provides a highly configurable platform based on a simple modular architecture. The Series feature set was carefully selected to enable drop-in replacement of many brands of mass flow controllers.

With the wide range of options and features available, the Series provides users with a single platform to support a broad range of applications.

Model can have a full scale flow as low as 3 ccm. With a high turndown ratio of repeatable gas flow can be measured or controlled down to 0. Model can Service and Support Brooks is committed to assuring all of our customers receive the ideal flow solution for their application, along with outstanding service and support to back it up.

We operate first class repair facilities located around the world to provide rapid response and support. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent.

You also have the option to opt-out of these cookies. But opting out of some of these cookies may have an effect on your browsing experience. Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information. This website uses cookies to improve your experience.

We'll assume you're ok with this, but you can opt-out if you wish. Cleanliness of the internal tube can also have an grooks on the instruments calibration. Through continual testing, the technicians at our Northeast Ohio calibration laboratory have noted issues that arise from a damaged or dirty tube. The severity can vary from a slight bend to a fully collapsed tube. A clogged or dirty tube will not provide accurate readings. Damage can impede or block flow. During the Brooks E mass flow controller calibration process, a technician verifies that the instrument is performing correctly.

If a mass flow controller fails testing, the technician will investigate the cause of the issue. If the internal tube is found to be damaged, the technician can replace it. If the e0 is found to be dirty or clogged, the technician can clean the tube depending on the severity of the clog. If the tube is found to be dirty or clogged, the technician can clean the tube depending on the severity of the clog.

The Brooks E mass flow controller is used to measure flow rate for aerospace, pharmaceutical, and energy industries. The heat is directed toward the center of the tube. If the internal tube is found to be damaged, the technician can replace it. A clogged or dirty tube will not provide accurate readings. Calibration testing will take place after tube replacement or cleaning. Click the button below to request a free quote from our accredited calibration lab. Chardon, Ohio Phone: If a mass flow controller fails testing, the technician will investigate the cause of the issue.

During flow, heat is moved away from the upstream sensor towards the downstream sensor.